Paw Taw John Services, Inc.
208-687-1478
Paw Taw John Services, Inc. Proportional Valve Tester PVT 2
Paw Taw John Services, Inc. Proportional Valve Tester PVT 2
Proportional Valve Tester PVT-2
In line electrical monitor for proportional hydraulic valves with on board electronics.
Designed to monitor those voltages which can affect the control of proportional hydraulic valves in a hydraulic system.
Configured for industry standard proportional valves (Bosch, Rexroth) operation on 24VDC, a +10VDC command signal.
TESTIMONIAL:
I am the Operations Manager at GPM Hydraulic Consulting and we have been using the Model PVT-02 proportional valve tester to troubleshoot proportional valves for our customers for many years now. We have purchased test boxes for all of our Consultants to use in the field when troubleshooting. This test box has saved us hours of troubleshooting and in return saved our customers hours of downtime. The box is connected in a series so you can observe the supply voltage, command signal and LVDT (linear variable differential transformer) feedback from the proportional valve while the system is running normally. You can also use the box instead of the PLC to drive the valve to see if the problem is the controller or valve itself. If you have proportional valves, you need to get one of these test boxes. Without the box to troubleshoot, your valves may get changed when there is nothing wrong with them. This box is also very affordable, a lot cheaper than what a proportional valve costs.
Last year I went on a consult for a company that made floor panels for BMW. A proportional valve is what controlled the press opening and closing but the press would not move. I connected the test box to their valve in series to watch the power supply, command and feed back voltages. When a command was given to lower the press, a power supply voltage of 22.6 volts was supplied to drive the valve amplifier. Normally the voltage should be 24 volts however, 22.6 was within the acceptable limits of operating the amplifier. The command voltage applied was 3.5 volts. The LVDT feedback voltage should have been 3.5 however,
- In line proportional valve tester uses system power
- Test proportional valves with On-Board Electronics (OBE)
- Limited capability for external drive valves
- Jog forward and reverse
- External command of valves or monitor while in use
- Monitors supply voltage, LVDT feedback and command voltages
- Optional carry-case available